METS SMILES Knee, Tibial rotating hinge metal cased assembly  - Uncoated knee tibia prosthesis, metallic Australia - English - Department of Health (Therapeutic Goods Administration)

mets smiles knee, tibial rotating hinge metal cased assembly - uncoated knee tibia prosthesis, metallic

stryker australia pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - the smiles tibial rotating hinge metal cased assembly consists of a uhmwpe tibial bearing with a co-cr-mo tibial component and titanium casing. stem lengths 140 or 180mm. knee components are available in small and standard sizes. an uhmwpe bumper available in both sizes provides a secondary bearing surface and a soft hyperextension stop, is pre-assembled within the tibial component. the tibial rotating hinge metal cased assembly is a component of the mets smiles total knee replacement which is intended for the replacement of diseased or deficient bone around the knee joint. indications: ? painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis or traumatic arthritis ? correction of varus, valgus or post traumatic deformity ? correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement ? ligament deficiencies ? tumor resections ? revision of previously failed total joint arthroplasty ? trauma

METS SMILES Knee, Tibial fixed hinge assembly - Uncoated knee tibia prosthesis, metallic Australia - English - Department of Health (Therapeutic Goods Administration)

mets smiles knee, tibial fixed hinge assembly - uncoated knee tibia prosthesis, metallic

stryker australia pty ltd - 32832 - uncoated knee tibia prosthesis, metallic - the smiles fixed hinge assembly is a co-cr-mo tibial component. stem lengths 140 and 180mm and are available in small and standard sizes. an uhmwpe bumper available in both sizes provides a secondary bearing surface and a soft hyperextension stop, is pre-assembled within the tibial component. the tibial fixed hinge assembly is a component of the mets smiles total knee replacement which is intended for the replacement of diseased or deficient bone around the knee joint. indications: ? painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis or traumatic arthritis ? correction of varus, valgus or post traumatic deformity ? correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement ? ligament deficiencies ? tumor resections ? revision of previously failed total joint arthroplasty ? trauma ? the fixed hinge tibial component is intended for limb salvage procedures requiring radical resection of bone and soft tissue.

METS SMILES,  Femoral knee component  - Uncoated knee femur prosthesis Australia - English - Department of Health (Therapeutic Goods Administration)

mets smiles, femoral knee component - uncoated knee femur prosthesis

stryker australia pty ltd - 32831 - uncoated knee femur prosthesis - the smiles femoral knee component is a cobalt-chromium molybdenum femoral component with a titanium stem. anatomical for left and right sides. available in small and standard sizes, with 140mm long femoral curved stem ?13mm for standard components and ?12mm for small components. a cobalt-chromium molybdenum axle, a pair of pre-assembled uhmwpe bushes and a titanium circlip are packaged with the femoral component.for cemented use. the femoral knee is a component of the mets smiles total knee replacement which is intended for the replacement of diseased or deficient bone around the knee joint. indications: ? painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis or traumatic arthritis ? correction of varus, valgus or post traumatic deformity ? correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement ? ligament deficiencies ? tumor resections ? revision of previously failed total joint arthroplasty ? trauma

METS SMILES Knee, Tibial rotating hinge polyethylene assembly - Uncoated knee tibia prosthesis, polyethylene Australia - English - Department of Health (Therapeutic Goods Administration)

mets smiles knee, tibial rotating hinge polyethylene assembly - uncoated knee tibia prosthesis, polyethylene

stryker australia pty ltd - 33580 - uncoated knee tibia prosthesis, polyethylene - a co-cr-mo tibial component with uhmwpe tibial bearing. stem length 114mm for standard and 105mm for small knee. an uhmwpe bumper available in both sizes provides a secondary bearing surface and a soft hyperextension stop, is pre-assembled within the tibial component. the tibial rotating hinge polyethylene assembly is a component of the mets smiles total knee replacement which is intended for the replacement of diseased or deficient bone around the knee joint. indications: ? painful and disabled joint resulting from avascular necrosis, osteoarthritis, rheumatoid arthritis or traumatic arthritis ? correction of varus, valgus or post traumatic deformity ? correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement ? ligament deficiencies ? tumor resections ? revision of previously failed total joint arthroplasty ? trauma

Orthodontic appliance, <specify> Australia - English - Department of Health (Therapeutic Goods Administration)

orthodontic appliance, <specify>

myosmiles - 34690 - orthodontic appliance, - a removable, functional appliance used by dentists to guide optimal dental and jaw development. this gentle approach helps eliminate noxious oral habits, promote nasal breathing and correcting the patient's dental occlusion